netBooter DX Series PDU – Overview

The netBooter DX Series is a smart switched Power Distribution Unit (PDU) designed for remote power control and management of distributed IT infrastructure. It combines secure remote access, outlet-level switching, environmental monitoring, VLAN-aware networking, and centralized fleet management, making it ideal for MSPs, retail chains, digital signage networks, and unmanned installations.


Key Features

Individual Outlet Control

  • Independently power cycle, turn on, or turn off each outlet remotely.
  • Enables rapid recovery of connected equipment without requiring onsite intervention.

Centralized Fleet Management

  • Manage multiple PDUs through a single cloud-based portal.
  • No need for complex firewall rules or port forwarding.

VLAN & Multi-Network Support

  • Full IEEE 802.1Q VLAN compatibility.
  • Supports segmented network deployments and multi-tenant environments.

Secure Remote Access

  • Access and control via:
    • HTTPS
    • SSH
    • SNMPv3
    • Central Management Portal

Zero-Touch Provisioning

  • Rapid deployment of configurations across multiple units.
  • Ideal for large-scale rollouts and distributed installations.

Inlet Current Monitoring

  • Real-time RMS current measurement.
  • Helps prevent overload conditions and improve power management.

Environmental Monitoring

  • Optional temperature and humidity sensing.
  • Supports proactive monitoring of equipment environments.

Enterprise Authentication

  • LDAP integration
  • RADIUS integration
  • Local user management

Event-Based Automation

  • Create automated actions based on:
    • Temperature thresholds
    • Humidity alarms
    • Network outages
    • Power events

Typical Applications

Managed Service Providers (MSPs)

  • Multi-site remote power management
  • VLAN-segmented customer environments
  • Remote recovery of SD-WAN appliances and customer-premises equipment

Retail Chains

  • Point-of-sale systems
  • Network switches and routers
  • LTE backup connectivity devices
  • Centralized branch management

Kiosks & Self-Service Systems

  • Interactive kiosks
  • Ticketing systems
  • Self-service terminals
  • Scheduled power cycling and automated recovery

Digital Signage Networks

  • Media players
  • Display controllers
  • Network equipment
  • Remote reboot and monitoring across distributed locations

Technical Specifications

Input Specifications

ParameterSpecification
Input ConnectorIEC 320 C14
Input Voltage100–120 VAC, 60 Hz or 100–240 VAC, 50–60 Hz
Maximum Current15 A (12 A derated)
PhaseSingle Phase
Input MeteringRMS Current Measurement

Output Specifications

ParameterSpecification
Outlet Voltage100–120 VAC or 100–240 VAC
Outlet TypesNEMA 5-15R or IEC 320 C13
Outlet Count2 or 5
Outlet SwitchingIndividual Outlet Switching
Outlet MeteringNone
Overload ProtectionNone

Networking & Security

Supported Protocols

  • HTTP / HTTPS
  • SSH
  • Telnet
  • SMTP
  • SNMP v1/v2/v3
  • DHCP
  • Syslog
  • Ping
  • NTP
  • IPv4
  • IPv6

Network Interface

  • 10/100 Base-T Ethernet (RJ45)

Security Features

  • Encrypted communication
  • LDAP authentication
  • RADIUS authentication
  • Local user accounts

Serial Connectivity

  • DB9 RS-232
  • USB

Front Panel Features

  • Individual outlet status LEDs
  • PDU power status LED
  • Network status LED
  • 7-digit LED display showing inlet current

Environmental Monitoring

Sensor Support

  • Temperature monitoring
  • Humidity monitoring

Compatible with:

  • SPA-0010 Temperature & Humidity Probe

Physical Specifications

ParameterCompact Model1U Strip Model
Outlets25
Dimensions6.2″ × 5.4″ × 1.75″19″ × 2.125″ × 1.75″
Form FactorCompact1U Rackmount

Environmental Ratings

  • Operating Temperature: -5°C to 60°C
  • Storage Temperature: -25°C to 65°C
  • Humidity: 5–95% RH (non-condensing)

Automation & Self-Healing Capabilities

The DX Series includes an automation engine that can:

  • Monitor network connectivity
  • Detect environmental changes
  • Trigger outlet power cycling
  • Send alerts and notifications
  • Execute recovery sequences
  • Trigger webhooks and external actions

This enables unattended systems to automatically recover from many common failures without human intervention.


SynLink SP Series vs netBooter DX Series

FeatureSynLink SP SeriesnetBooter DX Series
Outlet Control✔ Individual✔ Individual
Outlet-Level Power Metering✔ Yes✖ No
Inlet Energy Metering (kWh, PF, VA)✔ Yes✖ No
Environmental Monitoring✔ Advanced✔ Basic
ATS Models Available✔ Yes✖ No
Three-Phase Models✔ Yes✖ No
Outlet Count4–362–5
Data Center Deployment✔ ExcellentLimited
Distributed IT Sites✔ Yes✔ Excellent
MSP/Retail Deployments✔ Good✔ Excellent
Zero-Touch ProvisioningNot specified✔ Yes
Centralized Management Portal✔ Yes✔ Yes

Positioning

  • netBooter DX Series: Best suited for branch offices, MSPs, retail stores, kiosks, digital signage, and small distributed IT deployments where remote reboot and automation are the primary requirements.
  • SynLink SP Series: Designed for data centers, enterprise AV systems, laboratories, and mission-critical infrastructure requiring detailed power metering, ATS redundancy, environmental monitoring, and high-density power distribution.
Scroll to Top