Lantronix EDS-MD { Best Price In India } – Dealer

Lantronix EDS-MD-Wired IoT gateway for mission critical medical devices and equipment connectivity.

Contact us on team@bvmindia.in and Call: +91-9205161813

Category:

Manage Visibility into Medical Assets

The medical industry utilizes many connected devices and assets. A majority of these devices are critical to the operation of the medical enterprise, for example, patient monitors. The EDS-MD can be integrated into the medical enterprise’ network and enable visibility into these devices from anywhere, anytime.

Manage Mission-Critical Data Securely

The transport of sensitive information to and from remote device servers over the Internet demands the highest level of security. With Lantronix’ proprietary Secure Com Port Redirector™ virtualization software, existing serial port applications can work with EDS-MD without any code modifications. Virtual COM ports can be mapped to EDS-MD and encrypted at both ends of communication.

Manage Assets and Data Locally or Remotely

Management of any device and data requires fault-tolerance. EDS-MD empowers authorized IT staff to access and monitor devices and data anywhere, anytime. In addition, the EDS-MD goes beyond the IEC-60601 requirement, as it provides galvanic isolation on all ports to ensure the highest levels of safety and fault-tolerance. Should a grounding issue ever occurs, the operation of EDS-MD or other connected devices will not be affected.

High-Performance Wired Connectivity

The EDS-MD offers 4, 8 or 16 individually isolated RS-232 serial ports with a Gigabit (10/100/1000Mpbs) network interface. The configuration and setup of the EDS-MD is simple with industry-standard management tools including integrated Web and CLI interfaces along with XML support.

Specifically designed for the medical industry, the UL and IEC-60601 compliant EDS-MD provides mission-critical device connectivity, allowing remote access and management of virtually any electronic or medical device.EDS-MD offers the benefit of 4, 8 or 16 individually isolated RS-232 serial ports with a Gigabit (10/100/1000Mpbs) network interface. Going above and beyond the IEC-60601 requirement, EDS-MD provides galvanic isolation on all ports to ensure the highest levels of safety. If a grounding problem occurs, the operation of EDS-MD or other connected devices will not be affected.

With Lantronix’ proprietary Secure Com Port Redirector virtualization software, existing serial port applications can work with EDS-MD without any code modifications. Virtual COM ports can be mapped to EDS-MD and encrypted at both ends of the communication, allowing the transport of sensitive information to and from remote device servers over the Internet with the highest level of security.

Set up and configuration of EDS-MD is simple with industry-standard management tools including Web, CLI, XML.

Centralized Management via ConsoleFlow™

EDS-MD – Certified Multi-Port Wired IoT Gateway for Medical Devices

 

EDS-MD Tech Specs

Standards

  • IEEE 802.3
  • IEEE 802.3u
  • IEEE 802.3ab
  • USB 2.0

Hardware

  • 600MHz ARM 11 processor
  • 8 MB Flash
  • 4 GB SD Card (internal only)
  • 256 MB DRAM
  • Real Time Clock with Battery back-up
  • Onboard Thermal Sensor

Physical Interface

  • 4/8/16 RJ45 (DTE) Serial Connectors
  • RS-232 Interface
    • Data rates – up to 921 Kbps
    • ESD Protection – 15kV
    • Circuit and port isolation – 1.5KVAC
  • 2 USB Host ports – USB-A receptacle connectors
    • Output Capability = 0.5A
    • Circuit and port isolation – 1.5KVAC
  • 3 Ethernet port – RJ45 connector ^
    • 10/100/1000Mbps
    • Autosensing MDI/MDIX
    • Full/half duplex
    • Circuit and port isolation – 1.5KVAC
  • 1 Reset Button

^ 2 additional Ethernet ports enabled with future firmware release.

Protocols

• DHCP Client, DHCP Server, DHCPv6 Client
• uPnP (Discovery), LCAP (77FE), Telnet, FTP, HTTP(S)
• IPv4/IPv6, TCP, UDP, ICMP, ARP, Auto-IP, DNS, SNMP v2/v3

LED Indicators

  • Power/System
  • Serial Ports (4, 8, 16)
  • Ethernet – Activity/Link

Physical Dimensions

  • Size: L x W x H
    • 21 cm (8.25 in) x 19 cm (7.5 in) x 6 cm (2.4 in)
  • Weight:
    • 16-Port = 0.9 Kg (2.0) lbs
    • 8-port = 0.82 Kg (1.8 lbs)
    • 4-port = 0.8 Kg (1.75 lbs)

Software

• Network Time Protocol(NTP) support
• AES 192 & 256 bit encryption support
• Supports copying port config settings
• Gateway Features – port forwarding,
static routers and DHCP servers

Security

  • SSLv3, TLS1.0, TLS1.1 Client and Server – up to 4096-bit certificates.
  • Encryption: AES
  • Authentication: SHA-1, MD5, Base-64

Management

  • Centralized Management via ConsoleFlow™
  • Web Browser (SSL option for secure login)
  • CLI (over Serial Ports, Telnet or SSH)
  • XML Configuration Records via CLI or FTP

Environmental

  • Operating Temp: 0°C to +50° C (32°F to 122°F)
  • Storage Temp: -30°C to +80° C
  • Relative Humidity (Operating): 20% to 90%  non-condensing
  • IP Rating = 20

Power

  • Input: IEC60320 C14 receptacle without a power switch
  • 100-240 VAC, 50/60 HZ, 0.4A
  • Power Consumption: 23 Watts Max
  • Nominal Power: 12 Watts

Mounting

  • Wall mount
  • Desktop

Certifications

  • Emissions:
    • FCC part 15 Subpart B
    • EN 60601-1-2: 2007
    • Industry Canada ICES-003 Issue 4 February 2004
    • CISPR 22:2005 + A1: 2005 + A2: 2006 ITE
    • CISPR 11:2003 + A1: 2004 + A2: 2006
    • VCCI V-3/2010.04
    • AS/NZS CISPR 22: 2009
    • EN 55022: 2006 + A1: 2007
    • EN61000-3-2: 2006 + A1: 2009 + A2: 2009
    • EN61000-3-3: 2008
  • Immunity:
    • EN55024 1998 + A1: 2001 + A2: 2003
    • EN60601-1-2: 2007
    • EN61000-4-2: 2009
    • EN61000-4-3: 2006 + A1: 2008
    • EN61000-4-4: 2004 + A1: 2010
    • EN61000-4-5: 2006
    • EN61000-4-6: 2009
    • EN61000-4-8: 1994 + A1: 2001
    • EN61000-4-11: 2004
  • Safety:
    • UL 60950-1: 2nd edition; US Safety Standard for Information Technology Equipment
    • UL 60601-1: 1st edition; US Safety Standard for Medical Electrical Equipment
    • CAN/CSA-C22.2; No. 60950-1-07: 2nd edition; Canada Safety Standard for Information Technology Equipment
    • CAN/CSA C22.2; No. 601.1: 1990; Canada Safety Standard for Medical Electrical Equipment
    • IEC 60601-1: 1998 (2nd edition); International Safety Standard for Medical Electrical Equipment
    • EN60601-1: 1990 (2nd edition) Medical Electrical Equipment –Part 1: General Requirements for Safety
    • JIS T 0601-1:1999, Japan Safety Standard for Medical Electrical Equipment
Scroll to Top