USBHub3+ is a 9-port, software controlled, programmable USB hub with per-port power control designed for the most demanding industrial and business environments. Ideal for conference rooms, testing or development environments where standard “always-on” behavior of a consumer-grade USB hub is not desirable. Expand to multiple hubs via expansion port. See our blog post about port density.
PAINLESS PRESENTATIONS
With Acroname’s auto-switching technology, when a user’s host device (Laptop) is plugged in to the USBHub3+ Up0 port, any USB peripherals connected to USBHub3+ will then automatically switch to that user’s host device.
COMPLETE CONTROL
The USBHub3+ is an intelligent USB hub with per-port control. Eight (8) down-stream programmable USB-A ports with individual on/off control that can measure individual port voltage, current and data speed. Perfect for device testing and software regression labs where device charge control is needed to mitigate battery-swell.
COLD SECURE BACKUPS
USBHub3+ gives you the power to create cold secure daily offline backups with just a small script. Preventing takedowns from ransomware.
INDUSTRIAL GRADE RELIABILITY
The USBHub3+ is built for the most demanding conditions when failure isn’t an option. With a rugged steel enclosure, ±15kV ESD protection, and DIN rail mountable. It is ready for the harshest of factory floors, device farms, laboratories, or CEO-laden conference rooms.
POWERFUL AND FULL OF POWER
While most USB hubs struggle to charge a phone, the USBHub3+ can supply up to 5A on all ports with a maximum total power of up to 70W. This hub will not even break a sweat with eight 4k cameras connected.
The USBHub3+ is DIN Rail mountable using the C31-DINM-1.
FEATURES
- Supports USB hosts and devices up to USB 5Gbps; backwards compatible with USB1, USB2
- Individually enable/disable any of 8 downstream ports
- Measure voltage and current on each downstream port
- Hi-Speed data, SuperSpeed data and power lines can be separately enabled for each downstream port
- Set programmable current limits for each downstream port (up to 4A)
- Dedicated Control Port for software control; independent of the selected upstream port
- Select between two (2) host connections
- All ports support USB link speeds up to 5Gbps
- Detect established link speed on each port: SuperSpeed (5Gbps) or Hi-Speed (480Mbps)
- Supply up to 5A per port; measure upto 4A
- Set enumeration delay for discovery of attached downstream devices
- Backward compatible with USB 2.0 and USB 1.x devices
- Boost USB 2.0 upstream and downstream signal levels
- DIN-rail mountable
- Alternate Euro-style terminal block power input connector
- Certified to +/-15kV ESD strikes (IEC61000-4-2 level 4)
- Overvoltage and reverse current protected Vbus outputs
- Monitor voltage and current on any/all ports
- Maintain selectable control of data, SS lines, power lines for any port
- Enable/Disable any downstream port.
TYPICAL PERFORMANCE CHARACTERISTICS
Specifications are valid at 25°C unless otherwise noted. Indoor application uses only. Sample rates are typically limited by the USB throughput of the host operating system except where bulk capture is supported.
Parameter | Conditions/Notes | Min | Typ. | Max | Units |
---|---|---|---|---|---|
Input Power, Wsupply, no downstream devices attached | – | 2.2 | – | W | |
Vsupply Under Voltage Lockout (UVLO) | 7.7 | 8.0 | 8.2 | V | |
Vsupply Over Voltage Lockout (OVLO) | 26.0 | 26.8 | 27.8 | V | |
Wide Input Range System Efficiency | At 12.0V input, nominal 8A load3 | 84 | – | 92 | % |
USB Downstream Output Voltage, Vbus | No load on downstream USB ports | 4.947 | -5.10 | 5.25 | V |
Vbus Measurement Resolution | – | 8.0 | – | mV | |
Vbus Measurement Accuracy | -2.0 | – | 2.0 | % | |
Vbus Short-circuit Trip Current, Ilimit | 4.8 | 5.0 | 5.4 | A | |
Vbus Short-circuit Trip Time, tlimit | – | 0.7 | – | µS | |
Vbus Short-circuit Average Current, Ishort | After trip | 0.3 | 0.5 | 52.0 | A |
Vbus Current Measurement Resolution | – | 1.0 | – | mA | |
Vbus Current Measurement Accuracy | Vbus current < 4.00A | -1.0 | – | 1.0 | % |
Vbus Current Measurement Range | 0 | – | 4095 | mA | |
Vbus Current Limit Trip Point Range | Software programmable | 0 | – | 4095 | mA |
Vbus Current Limit Trip Point Resolution | – | 1.0 | – | mA | |
USB3 SuperSpeed Data Throughput | 5.0 | Gbps | |||
USB2 HighSpeed Data Throughput | 480 | Mbps | |||
MTBF (hub assembly only) | 92.8 | Years | |||
FIT (60% confidence; hub assembly) | 1230 | failures per one billion hours | |||
MTBF (hub plus included power adapter) | 5.3 | Years | |||
FIT (60% confidence; hub plus power adapter) | 21229 | failures per one billion hours |