The OpenBCI EEG Electrode Cap is engineered for reliable EEG bio-potential measurements with wet electrodes. The product comes in two variants:
- 21-channel electrode cap with removable, Ag/AgCl coated electrodes
- Premium 21-channel electrode cap with patented, sintered Ag/AgCl electrodes
Note, electrode gel and touchproof adapter must be purchased.
Product Features:
- Contents are: a cap with electrodes, a syringe, and a cleaning brush.
- Sleek, compact design for wet electrode EEG measurements
- Engineered to combine the best of signal quality and comfort
- Suitable for sleep studies
- Compatibility with all OpenBCI boards and standard touch-proof connectors
- Compatibility with OpenBCI’s FREE open-source software
- Compatibility with most bioamplifiers
- Electrodes located and labeled using the internationally recognized 10-20 system
- Comfortable, easy-to-clean mesh cap
- Adjustable chinstrap for stability and reduction in movement artifacts
- Insulated leads secured with built-in elastic tabs
- Built-in durable sleeve for cable management
- Comes in two Ag-AgCl electrode variants, coated and sintered
- Three size options, S,M, and L
The leads terminate in industry-standard 1.5mm Touch-Proof connectors and can be connected to the Cyton 8-channel or CytonDaisy 16-channel board with an electrode adapter. Please note: these items are not included in this kit!
Interested in an all-inclusive hardware set-up? View the All-in-one EEG Electrode Cap Starter Kit!
View the FAQ and Getting Started Guide
Important Notes:
- Electrode gel is required and sold separately. Purchase the recommended product HERE.
- Cleaning the cap properly after use is very important and will substantially increase the longevity of the product. A brush for cleaning the cap is included!
- The premium electrode cap with sintered AgAgCl electrodes is resistant to the corrosion of wet electrodes associated with repeated use. The sintered material is conductive throughout; a layer can be scraped off in the event of corrosion, restoring the signal quality. The sintered cap is longer-lasting and more durable. This cap has gray plastic guards around the electrodes (see product images).
- It has been well-established by that sintered Ag-AgCl electrodes are superior to other types of commercially available electrodes, as compared here and here in Clinical Neurophysiology.
- After 25-50 uses, corrosion of coated Ag/AgCl electrodes may require replacement of the cap if not maintained by cleaning, due to compromised conductive layer. This cap has black rubber guards around the electrodes (see product images)
- Be sure to choose your size from the dropdown menu! See instructions below.
NIH-Published Research on Advantages of Sintered Electrodes for EEG:
Evaluation of commercially available electrodes and gels
Want to see more use cases of OpenBCI? Head to our keyword searchable collection of recently published, OpenBCI-based EEG, EMG, and ECG research
Size Guide:
Be sure to get the right size for your head! Obtain the circumference using a tape measure wrapped horizontally across the widest part of your head.
- Small = 50-54cm (best for children)
- Medium = 54-58cm
- Large = 58-62cm
- If between sizes, please size up
Disclaimer:
The OpenBCI Electrode Cap is not a medical device nor is it intended for medical diagnosis and provided to you “as is,” and we make no express or implied warranties whatsoever with respect to its functionality, operability, or use, including, without limitation, any implied warranties, fitness for a particular purpose, or infringement. We expressly disclaim any liability whatsoever for any direct, indirect, consequential, incidental or special damages, including, without limitation, lost revenues, lost profits, losses resulting from business interruption or loss of data, regardless of the form of action or legal theory under which the liability may be asserted, even if advised of the possibility of such damages